How to size a heat pump for your house (kW) — the method without magic numbers (2026)

Updated: 2026-10-02 · ~2 min read

Status: October 2, 2026. Figures are indicative; final sizing is done by the installer after a heat-loss audit.

Why capacity matters

  • Too small — the backup (electric/gas) takes over for most of winter; bills grow and the real system COP drops.
  • Too big — you pay more per kW (the biggest cost factor in the investment), short compressor cycling, faster wear.

Estimating demand (three steps)

  1. Annual specific demand in kWh/m²·year: well-insulated new house ~40–80; renovated ~80–130; old uninsulated ~150–250. This is the first filter — without insulation, no heat pump will be optimal.
  2. Peak demand (kW): the installer calculates heat loss (standard energy-audit method). Rule of thumb: the heat pump should cover most of the load at the design outdoor temperature (typically −7…−10 °C in this climate), and the backup covers the coldest days.
  3. Add DHW: domestic hot water typically adds 1.5–3 kW on top of space-heating peak.

Benchmark for typical houses (table)

House type (120 m²)Annual demandTotal capacity incl. DHW (indicative)
new, well insulated (≤80 kWh/m²·yr)~5–10 MWh/yr8–12 kW
renovated / average insulation~10–16 MWh/yr12–16 kW
old, poorly insulated (>150 kWh/m²·yr)~18–30 MWh/yr16–24 kW — check retrofit economics first

Signs the sizing failed

  • Backup runs regularly below −7 °C (visible in logs/app) → capacity shortage.
  • Winter electricity bill clearly above the indicative range in the seasonal-cost article → undersizing or bad settings.
  • The pump starts/stops every few minutes (short cycles) → possible oversizing relative to the load.

What to demand in the installer’s quote

  1. Capacity chosen from a heat-loss calculation, not “from the catalogue”.
  2. SCOP stated for your configuration (floor heating/radiators, buffer, climate zone).
  3. A clear description of the backup (power, source, control logic).